dc.descriptionEl hormigón reciclado es una excelente opción en cuanto a la sostenibilidad en la industria de la construcción. Sin embargo, los agregados constituidos por hormigón triturado usualmente poseen una alta porosidad y puede resultar en detrimento de la durabilidad de las armaduras. En este trabajo se expone un estudio sobre hormigones reciclados armados, de relaciones agua/cemento 0,40, 0,50 y 0,60, adoptando dos espesores de recubrimiento. Se analizaron los comportamientos frente a parámetros relacionados con la corrosión de armaduras como son el potencial de corrosión, la corriente de corrosión y el contenido de cloruro. Las mediciones fueron realizadas en muestras expuestas en ambiente marino durante un período de 50 meses. Finalizada la exposición, se corroboró visualmente el estado de las armaduras. Los resultados muestran, como era de esperar, una clara influencia de la relación a/c en el ingreso de cloruros, pero además indican la influencia sobre la velocidad de deterioro de la relación a/c una vez despasmadas las armaduras, así como contenidos umbrales de cloruros para estos hormigón reciclados. Finalmente se valora la corrosividad de las armaduras en hormigón reciclado en función del espesor de recubrimiento y la relación agua/cemento.-
dc.descriptionRecycled concrete is an excellent option as regards the sustainability of construction industry. Nevertheless, aggregates constituted by crushed concrete usually have high porosity and this can be harmfull to reinforced durability. In this paper, a study on reinforced recycled concrete, using w/c ratios (0.40, 0.50, 0.60) and two cover depths is presented. Parameters related to reinforcement corrosion as corrosion potential, corrosion current and chloride content were analyzed. Measurements were performed on specimens exposed in marine environment for a period of 50 months. At the end of the exposure period, the state of reinforcement was visually corroborated. The results show a marked influence of w/c ratio on the chloride ingress. They also indicate an influence of the w/c ratio on the deterioration rate after the depassivation of rebars, as well as a range of threshold chloride content for the studied recycled concretes. The reinforcement protection capacity of recycled concrete is shown.-
dc.formatapplication/pdf-
dc.formatp. 7-18-
dc.languagespa-
dc.publisherLaboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica (LEMIT)-
dc.rightsinfo:eu-repo/semantics/openAccess-
dc.rightsAttribution 4.0 International (BY 4.0)-
dc.sourcereponame:CIC Digital (CICBA)-
dc.sourceinstname:Comisión de Investigaciones Científicas de la Provincia de Buenos Aires-
dc.sourceinstacron:CICBA-
dc.source.urihttp://digital.cic.gba.gob.ar/handle/11746/487-
dc.subjectIngeniería de los Materiales-
dc.titleCorosión de hormigón reciclado armado en ambiente marino-
dc.typeinfo:eu-repo/semantics/article-
dc.typeinfo:eu-repo/semantics/submittedVersion-
dc.typeinfo:ar-repo/semantics/articulo-
Aparece en las colecciones: Facultad de Ciencias Económicas. UBA

Ficheros en este ítem:
No hay ficheros asociados a este ítem.