Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.provenance | Comisión de Investigaciones Científicas | - |
dc.contributor | Borlando, Luis | - |
dc.contributor | Becka, Leopoldo | - |
dc.creator | Borlando, Luis | - |
dc.creator | Becka, Leopoldo | - |
dc.date | 1973 | - |
dc.date.accessioned | 2019-04-29T16:03:42Z | - |
dc.date.available | 2019-04-29T16:03:42Z | - |
dc.date.issued | 1973 | - |
dc.identifier | http://digital.cic.gba.gob.ar/handle/11746/927 | - |
dc.identifier.uri | http://rodna.bn.gov.ar:8080/jspui/handle/bnmm/308158 | - |
dc.description | Se realizaron ensayos para determinar la retención de creosota en albura de eucaliptus viminalis y saligna, utilizando la Norma ASTM-D-1 860 y algunas variantes de la misma. Se concluye que: la desviación normal estimada de las determinaciones (precisión) es de aproximadamente 1 % la diferencia entre los resultados obtenidos en tres laboratorios (reproducibilidad) es de aproximadamente 1 % la diferencia entre los valores obtenidos sobre pastillas cortadas de tarugos de 15 mm de diámetro y 2 cm de largo, y valores obtenidos sobre muestras de astillas tomadas de los 2 cm de corona exterior de tortas cortadas de los mismos postes es de 16 %, con desviación normal de 2 % la diferencia entre los valores de retención obtenidos luego de 7-8 meses de impregnación y los valores originales es de aproximadamente 1 %. | - |
dc.description | A series of creosote retention tests on sapwood of eu- caliptus viminalis and e. saligna were performed by using the standard ASTM-D-1 860 and some varying of it. Conclusions are obtained as follows: the estimated standard deviation of the determinations (precision) is about 1 %; the difference detected between results obtained in three laboratories (reproducibility) is about 1 % the difference detected in values obtained on samples made up by tablets obtained from cores of 15 cm of diameter and of 2 cm lenght, and those* obtained from samples made up by chips taken off the outer 2 cm zone from 30 cm specimens cutted from the aforesaid poles is of 16 % with a standard deviation of 22 %; the difference between the retention values obtained after 6 or 8 months of impregnation and the original values, is about 1 %. | - |
dc.format | application/pdf | - |
dc.format | p. 191-209 | - |
dc.language | spa | - |
dc.publisher | Laboratorio de Entrenamiento Multidisciplinario para la Investigación Tecnológica (LEMIT) | - |
dc.rights | info:eu-repo/semantics/openAccess | - |
dc.rights | Attribution 4.0 International (BY 4.0) | - |
dc.source | reponame:CIC Digital (CICBA) | - |
dc.source | instname:Comisión de Investigaciones Científicas de la Provincia de Buenos Aires | - |
dc.source | instacron:CICBA | - |
dc.source.uri | http://digital.cic.gba.gob.ar/handle/11746/927 | - |
dc.subject | Ingeniería de los Materiales | - |
dc.title | Método de determinación en laboratorio de retención de creosota en muestras de eucaliptus impregnados | - |
dc.type | info:eu-repo/semantics/article | - |
dc.type | info:eu-repo/semantics/publishedVersion | - |
dc.type | info:ar-repo/semantics/articulo | - |
Aparece en las colecciones: | Comisión de Investigaciones Científicas de la Prov. de Buenos Aires |