Registro completo de metadatos
| Campo DC | Valor | Lengua/Idioma |
|---|---|---|
| dc.provenance | CONICET | - |
| dc.creator | Treo, Ernesto Federico | - |
| dc.creator | Felice, Carmelo Jose | - |
| dc.date | 2018-12-05T18:01:21Z | - |
| dc.date | 2018-12-05T18:01:21Z | - |
| dc.date | 2009-11 | - |
| dc.date | 2018-11-13T17:09:04Z | - |
| dc.date.accessioned | 2019-04-29T15:45:18Z | - |
| dc.date.available | 2019-04-29T15:45:18Z | - |
| dc.date.issued | 2009-11 | - |
| dc.identifier | Treo, Ernesto Federico; Felice, Carmelo Jose; Design and evaluation of a fast Fourier transform-based nonlinear dielectric spectrometer; American Institute of Physics; Review of Scientific Instruments; 80; 11; 11-2009; 114301-114308 | - |
| dc.identifier | 0034-6748 | - |
| dc.identifier | http://hdl.handle.net/11336/65877 | - |
| dc.identifier | CONICET Digital | - |
| dc.identifier | CONICET | - |
| dc.identifier.uri | http://rodna.bn.gov.ar:8080/jspui/handle/bnmm/301181 | - |
| dc.description | Nonlinear dielectric spectroscopy of micro-organism is carried out by applying a moderate electrical field to an aqueous sample through two metal electrodes. Several ad hoc nonlinear spectrometers were proposed in the literature. However, these designs barely compensated the nonlinear distortion derived from the electrode-electrolyte interfaces (EEI). Moreover, the contribution of the suspension is masked by the effect of the nonlinearity introduced by the electrode contacts. Conversely, the nonlinear capability of a commercial tetrapolar analyzer has not been fully investigated. In this paper a new nonlinear tetrapolar spectrometer is proposed based on a commercial linear apparatus and ad hoc control and signal processing software. The system was evaluated with discrete electronic phantoms and showed that it can measure nonlinear properties of aqueous suspension independently of the presence of EEI (ANOVA test, p0.001). It was also tested with real aqueous samples. The harmonics observed in the current that circulates through the sample reveals useful information about the transfer function of the sample. The total harmonic distortion was computed for linear mediums. Values lower than -60 dB suggest that the system has enough capability to perform nonlinear microbiological analysis. Design specifications, sources of interference, and equipment's limitations are discussed. | - |
| dc.description | Fil: Treo, Ernesto Federico. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Departamento de Bioingeniería; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Juan; Argentina | - |
| dc.description | Fil: Felice, Carmelo Jose. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto Superior de Investigaciones Biológicas. Universidad Nacional de Tucumán. Instituto Superior de Investigaciones Biológicas; Argentina | - |
| dc.format | application/pdf | - |
| dc.format | application/pdf | - |
| dc.format | application/pdf | - |
| dc.language | eng | - |
| dc.publisher | American Institute of Physics | - |
| dc.relation | info:eu-repo/semantics/altIdentifier/url/https://aip.scitation.org/doi/10.1063/1.3247903 | - |
| dc.relation | info:eu-repo/semantics/altIdentifier/doi/https://dx.doi.org/10.1063/1.3247903 | - |
| dc.rights | info:eu-repo/semantics/restrictedAccess | - |
| dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | - |
| dc.source | reponame:CONICET Digital (CONICET) | - |
| dc.source | instname:Consejo Nacional de Investigaciones Científicas y Técnicas | - |
| dc.source | instacron:CONICET | - |
| dc.source.uri | http://hdl.handle.net/11336/65877 | - |
| dc.subject | BIOLOGICAL | - |
| dc.subject | IMPEDANCE | - |
| dc.subject | SUSPENSION | - |
| dc.subject | Ingeniería de Sistemas y Comunicaciones | - |
| dc.subject | Ingeniería Eléctrica, Ingeniería Electrónica e Ingeniería de la Información | - |
| dc.subject | INGENIERÍAS Y TECNOLOGÍAS | - |
| dc.title | Design and evaluation of a fast Fourier transform-based nonlinear dielectric spectrometer | - |
| dc.type | info:eu-repo/semantics/article | - |
| dc.type | info:eu-repo/semantics/publishedVersion | - |
| dc.type | info:ar-repo/semantics/articulo | - |
| Aparece en las colecciones: | CONICET | |
Ficheros en este ítem:
No hay ficheros asociados a este ítem.